Faze 180 Concealed Emergency Light
Brand: Philips Chloride
See PRODUCT DESCRIPTION below
This product is unavailable or discontinued. Please consider searching products in these related categories:
DESCRIPTION
*** DISCONTINUED, NO LONGER AVAILABLE. NO REPLACEMENT ***
Codes and Standards
- ETL Listed to UL924 Standard
- NFPA 101 (Life Safety Code)
- NFPA 70 (National Electric Code)
Voltage Input
- Dual Voltage 120/277 VAC
- Selectable Input
Construction
- The unit back box is constructed of code gauge cold rolled galvanized steel.
- The back box requires an 8-1/4" long x 7-7/8" wide cutout.
- Back box is universal to accommodate ceiling or wall mount applications.
- The trim plate and door assembly are constructed of die-cast aluminum.
Installation
- Ceiling or wall mounting in new construction.
- Easy installation via the single enclosure back box.
- Units in smaller backbox have built-in grid clips for use in T-grid ceilings.
- The FAZE180 unit is mounted in a wall or ceiling and the door is
closed under normal power conditions.
Lamps
- Fully adjustable MR16 halogen lamps with GU-10 bi-pin twist-lock base and are available in choice of 12W, 20W, 35W, 50W and 75W.
- Lamps have expected life of 2000-plus hours.
Battery
- Choice of 12V maintenance free sealed lead calcium battery with a service life of 5 to 7 years and an operating temperature range of 65°F (19°C) to 85°F (30°C) or 12V maintenance free nickel cadmium battery with a service life of 8 to 10 years and an operating temperature range of 20°F (-7°C) to 95°F (35°C).
- Both provide a minimum of 90 minutes emergency illumination.
Remote Capacity
- Select units have remote capability which can be used to power 12 volt remote lamp heads.
Warranty
- Five full year warranty on units. (Lamps not included.)
- Lifetime warranty on direct drive motor.
Electronics Xtest
- All units utilize a micro-processor and contain the Xtest self-test/self-diagnostic circuit.
- Each unit includes low voltage disconnect, AC lockout, and brownout protection.
- The FAZE180 unit will automatically conduct a self-test once a month to verify all systems are functioning properly.
- Several manual tests can also be initiated or cancelled at any time by pressing the test switch.
- During automatic self-test or manual test, the green AC status indicator will flash.
- Any malfunction is immediately reported via the appropriate external LED indicators.
- Upon loss of utility power, the door on the unit rotates 180° exposing two MR16 lamps which are immediately illuminated.
- When power is restored, the lamps are turned off and the door rotates back to the closed position.
Motor
- The door of the FAZE180 series is actuated by a direct drive bidirectional heavy-duty motor.
- This motor has a lifetime guarantee.
Automatic Test
- The system charger and lamps are continually being controlled via pre-determined parameters specific to each model configuration automatically. The battery is controlled via a true open circuit test each hour after initial installation. Once each month the Xtest System illuminates lamps under load for 60 seconds behind closed door, simulating a power outage with a true charger off condition, without affecting long-term battery life. This is above and beyond the requirements of the National Electric Code and/or the National Fire Protection Association, which only requires a 30 second automatic test once every month. This gives you unequaled control and confidence, knowing you are meeting self-test code requirements each and every month.
Manual Test
- A manual test switch allows for the system to perform the
following tests at any time:
Press Button:
Once - 5 second test, charger off, no load
Twice - 60 second test, charger off, lamps on
Three - 90 minute test, charger off, lamps on
6-Second Hold - Fully reinitializes micro-processor.
Pressing once during any test will cancel/abort testing.